Passive Chlorination: Providing Clean Drinking Water to Ecuadorian Communities
In 2002, WHO reported that nearly 1.7 million deaths worldwide were caused by unclean water. The risk of death by unclean water is elevated for young children, for which the second cause of death worldwide is diarrheal disease, which is largely caused by microbes; these microbes, when unaddressed, can proliferate in drinking water. Health risks are further elevated in rural communities, which often lack access to the technology necessary to treat water for microbial contamination. This can be seen in Ecuador, in which only 52.8% of rural households have access to safe drinking water.
The problem of infected drinking water in rural communities begs the question: how does  one effectively eliminate the risk of microbial contamination without the use of electricity and  complex, expensive components? A solution: passive chlorination. Passive chlorination systems  use the flow of the water itself to release chlorine into the water. The chlorine then disinfects  the water, leaving it safe to drink.
The research that I conducted this summer, in conjunction with related research  conducted by a team of professors and engineering students, primarily involved assembling and  testing a chlorinator that was determined by literature review to be the most promising option  of several different passive chlorinators. The CTI-8, designed by Compatible Technology  International, is a low-cost chlorinator that can be made using hand tools and commercially  available PVC components. Using the provided instructions for building a CTI-8, I constructed and  tested one in a model system that was meant to mimic the flow conditions in Ecuadorian  communities. The model system was comprised of a hose-fed 50 gallon upper tank, a main pipe  line that split into two lines (one with the CTI-8 and one without it), a bypass valve, and a 50  gallon lower tank into which both lines drained. This model system provided a way to run a series  of experiments to determine the dosing capabilities of the CTI-8, and to determine how to adjust  the bypass valve that controlled the ratio of water that went through the chlorinator versus the  ratio that bypassed the chlorinator.
The ability to control this ratio proved to be a very reliable means of controlling the final  combined concentration of the two lines. If more chlorine was needed in the lower tank, the  amount of water bypassing the chlorinator was reduced, and vice versa. Additionally, the CTI-8  proved to be very effective at consistently dosing water for a wide range of flow rates. For this  reason, the CTI-8 will be implemented for an Ecuadorian community by July 2023.  Working with a team to develop and test a real-world solution has been eye-opening to  the multi-faceted nature of real-world engineering problems. In the case of Ecuador, access to  clean water is a societal, economic, and technological issue, making it a challenge to create an  appropriate solution that meets the needs of Ecuadorian communities.
Student researchers
Kyle Borror